Get In Touch
541 Melville Ave, Palo Alto, CA 94301,
ask@ohio.clbthemes.com
Ph: +1.831.705.5448
Work Inquiries
work@ohio.clbthemes.com
Ph: +1.831.306.6725

Marking

ATEX:
Ex II 2G Ex eb ia ib IIA, IIB or IIC T6, T5, T4 oder T3 Gb
Ex II 2G Ex tb ia ib IIIA, IIIB oder IIIC, T80°C, T95°C oder T130°C Db

IECEx:
Ex eb ia ib IIA, IIB, or IIC T6, T5, T4, or T3 Gb
Ex tb ia ib IIIA, IIIB, or IIIC, T80 °C, T95 °C,or T130 °C Db

Ambient Temperature

Dependent on installed components. Please pay attention to the information on the marking plate.
-60 °C to max. +80 °C (-76 °F to max. +176 °F)

Certification

  • ATEX
    • EN
  • IECEx
    • EN
  • CCC
    • KO
  • EAC
    • RU

Polyester distribution boxes have been of great advantage in many industrial plants. They offer safe protection even when they are exposed to extreme environmental conditions, aggressive chemical media or high mechanical stress. The narrow sides within the enclosure hold threaded bushings for the fixing of terminal rails or mounting panels. The enclosure is mounted by means of insulated screws outside of the lid sealing gasket.
These black high-quality explosion-proofed enclosures are used in hazardous areas by inflammable gas (Zone 1 and 2) and dust (Zone 21 and 22). The fundamental prerequisites of the “protection through enclosure“ protection class are fulfilled with the heating up calculation as per the accompanying sheet and a separate IP protection test.

Technical Data

Protection class IP66 (IEC/ EN 60529)
Dimensions see data sheet
Material glass-fiber reinforced polyester, EN 60079-0
halogen-free, RAL 9005 (black) or RAL 7000/7001 (grey)
Weight see datasheet
Voltage max. 1000 V
Current see operating instructions
Surface resistance black enclosure (RAL 9005) 10^9 Ω
grey enclosure (RAL7000/7001) > 10^12 Ω

Questionnaires/Requirement Sheets

Customer requirements
  • DE
  • EN
  • FR
  • RU

Manuals/Operating Instructions/Guides

  • Operating instruction
    • DE
    • SP
    • EN
  • Current load value tables
    • EN
  • Chemical resistance of GRP enclosures
    • EN

Declarations

EU Declaration of Conformity
  • EN-DE-FR

Data Sheets

  • Data Sheet
  • Data sheet Junction & Terminal boxes – general