Marking ATEX certified IECEx certified W&M/MID certified Ambient Temperature Operating Temperature: -20°C to +50°C (-4°F to 122°F) Certification W&M/MID
Storage Temperature: -20°C to +50°C (-4°F to 122°F)
DE
EN
NL
The PETRO 3003 Volutiger | Volubottle system for the combined delivery of bulk and small quantities is the most powerful on the market right now. The unique integration of measured direct gravity and pumped delivery in only one PETRO 3003 system is capable of performing any type of delivery. The fully electronic dipstick system precisely measures the volume in the compartments during all operational steps of the transport cycle, combined with an optional turbine meter for small-quantity deliveries.
The PETRO 3003 Volutank system can easily be extended with:
- Sealed parcel delivery “SPDS” (EN 15208)
- Over-fill prevention
- Cross-over prevention “SAFE” (EN 14116)
- Opticontrol
- Office communication and connection via GPRS
- etc.
Technical Data
| Operating System: | LINUX |
|---|---|
| Type of instrument: | Metrology-approved level measuring instrument with float + measuring turbine (optional) |
| Measurand: | Volume (in connection with a filling table of the measuring tank) |
| Measurement range: | Range of dipstick to 3000 mm |
| Type of liquid: | Liquids in the viscosity range < 20mPas at 20°C
(Gasoline, Diesel, Heating oil, Jet fuel, Biodiesel, etc.) |
| Flow rate: | Maximum possible flow (e.g. 1,000 l/min or more per compartment) |
| Accuracy class: | Better than 0.1 (field-proven) |
| Total Weight : | Starting at 81 kg |
Documents
Brochure VOLUTANK
- DE EN TR
Brochure SAFE/SPDS
- DE, EN, TR
Brochure Opticontrol
- DE, EN
Operating Manual
- DE, EN
Service Manual
- DE, EN
Brochure
- EN
Configuration Manual
- DE, EN
Quick Guide
- BG, CS, DA, DE, EN, ET, FR, HR, HU, IT, LT, LV, NL, PL, RO, RU, SK, SL