Marking
ATEX:
Ex II2GD
Ex db IIB+H2 Gb or Ex db IIC Gb
Ex tb IIIC Db IP66
IECEX:
Ex db IIB+H2 Gb or Ex db IIC Gb
Ex tb IIIC Db IP66
Ambient Temperature
-60°C to +200°C
(except pilot lights)
-60°C to +95°C
(pilot lights only)
Certification
-
ATEX
- EN
-
IECEx
- EN
-
NEC505
- EN
-
INMETRO
- PT
-
KC
- KO
A large variants and versions of Ex d actuators, like:
– Spring return push buttons with or without padlockable device
– Pilot lights
– Illuminated spring return push buttons
– Relase by key and/or turn to release mushroom type emergency push buttons
– Control handles for every rotary switches, on-load switches, MCB, and MCCB, with or without padlockable device.
Technical Data
| Protection class | IP66 (IEC/EN 60529) |
|---|---|
| Dimensions | see data sheet |
| Material | Stainless steel Nickel plated brass Polycarbonate Aluminium light alloy |
| Contact material | Copper |
| Mechanical life | B10d = 600,000 |
| Weight | see data sheet |
| Voltage | see data sheet |
| Current | see data sheet |
| Impact test | 7 Joule Passed |
Manuals/Operating Instructions/Guides
-
ATEX – Instruction for use
- EN
- IT
-
NEC505 – Instruction for use
- EN
-
KC – Instruction for use
- EN
- KO
Declarations
-
ATEX – Declaration of conformity
- EN
- IT
-
IECEx – Declaration of conformity
- EN
- IT
Data Sheets