Marking ATEX: IECEx: Ambient Temperature -40 °C to +110 °C Certification IECEx
Ex II 2 G Ex db IIC Gb
Ex db IIC Gb
EN
ATEX
EN
The TNDLDE range of line bushings are designed as components for use in all Ex de enclosures to pass connection between the Ex d and Ex e compartment in combination Ex de enclosures. The TNDLDE is designed to accommodate coaxial cables such as RG179 (50 Ohm) or can be manufactured to order for custom or hybrid bushing requirements.
Technical Data
| Material | Centre conductor: Copper Ø 2.25 mm Dielectric: REX (Polyethylene cross-linked) Ø 7.25 mm Outer conductor: Copper, Silver plated, braid, 95%, Ø 8.15 mm Jacket: RADOX (LSFH), RAL 9005 – bk 10.3 mm ±0.1 Print: HUBER+SUHNER GX 07272 50W (PA no.) |
|---|---|
| Weight | 16.1 kg/100 m |
| Voltage | Max. operating voltage: 5 kVrms (at sea level) Test voltage: 10 kVrms (50Hz/1 min) |
| Resistance | Insulation resistance >1 x 108MΩm |
| Frequency | Max. Operating frequency: 2 GHz |
Manuals/Operating Instructions/Guides
User Manual – TNDLD
- EN
Declarations
Declaration of Conformity TEC-16-ATEX-TNDLD-01
- EN
Data Sheets
Data Sheet – Flameproof Enclosures