Ambient Temperature

Operating temperature
Standard:
-30 °C to +60 °C
(-22 °F to +140 °F)

Extended:
-50 °C to +60 °C
(-58 °F to +140 °F)

Motor Purge Control System consisting of a Motor Purge Controller – APEXmpc or SILASmpc and a Motor Purge Valve – mpv (pressure monitor) is a unit allowing a safe operation of electric motors in a hazardous environment.The explosion protection is ensured by means of a pressurized enclosure with leakage loss compensation. The Motor Purge Control System monitors, controls and regulates the purging gas supply for the Ex p motor. Any malfunctioning in the system or the purging gas supply will be reported reliably and deactivated by safely isolating the Ex p motor.

Technical Data

Protection class IP 65
Structure valve-controlled outlet for MPC
Pressure relief: integrated, opens at 50 mbar
Flying spark and particle barrier: integrated
Dimensions see data sheet
Material Stainless steel (V4A), (Sheet steel on request)
Installation Mounting: Horizontal or vertical
Connection Connections: 2 x pipe connection 10 mm
Connection flange: DIN2633 NW 50 PN16 (MPV 2)
DIN2633 NW 100 PN16 (MPV 3)
(See Operating Instructions for dimensions)
Ex p Control Unit APEXmpc or SILASmpc

Data Sheets

Data Sheet – Motor Purge Valve – MPV