Marking

N/A

Ambient Temperature

Temperature resistance -50 °C to +180 °C

The SCR sensor cable is used for detecting electrically conductive liquids such as water.
This sensor cable can detect the location of the leak precisely.
The SCR is a 4-core flexible round cable with protective braiding.

Technical Data

Structure Sensors: 2 x 0.25 mm²,
protected by partially permeable PTFE insulation
Colour: red, white
Rated resistance: 6 Ohm/mReturn conductor: 2 x 0.25 mm² with FEP
Colour: red, white

Protective braiding made of FEP
Colour: natural

Dimensions Cable diameter: 5 mm
Minimum bending radius: 6 x cable diameter

Manuals/Operating Instructions/Guides

  • User Manual SCR
    • DE
    • EN
    • FR

  • Assembly Instructions SCR
    • DE
    • EN
    • FR
Data sheets
Datasheet SCR