Get In Touch
541 Melville Ave, Palo Alto, CA 94301,
ask@ohio.clbthemes.com
Ph: +1.831.705.5448
Work Inquiries
work@ohio.clbthemes.com
Ph: +1.831.306.6725

Marking

ATEX:
Ex II 2G Ex mb IIC T4 Gb
Ex II 2D Ex mb IIIC T130°C Db

IECEx:
Ex mb IIC T4 Gb
Ex mb IIIC T130°C Db

Ambient Temperature

Operating temperature
-40 °C to +40 °C @ T4
(-40 °F to 104 °F @ T4)

Storage temperature
-20 °C to +60 °C
(-4 °F to 140 °F)

Certification

ATEX Zone 1/21
DE
EN
IECEx Zone 1/21
EN

The proportional purging gas valve activated by the APEX control unit conducts the supplied purging gas into the Ex px control cabinet. During the purging phase the purging gas valve opens far enough to allow the max. purging gas pressure to be reached and accordingly ensures purging pressure in the encapsulated control cabinet. After the purging phase the purging gas valve closes. The leakage from the Ex px control cabinet is compensated by the linear opening of the valve. Only the actual loss by leakage is compensated when the purging gas valve is used.

Technical Data

Protection class IP 65
Dimensions see data sheet
Max. Ex px control cabinet capacity: 1,000 litres
Pressure 0 to 3.5 bar
Weight approx. 1.2 kg
Voltage DC 24 V/15 W
Voltage tolerance: ± 10%
Connection Valve connection: G 3/8″
Nominal diameter: 6.0 mm

Declaration

Declaration of Conformity – Type 2865

  • DE
  • EN
  • FR

Data Sheets

Data sheet proportional purge gas valve

This website stores cookies on your computer. Cookie Policy