Marking ATEX: IECEx:
Ambient Temperature -25 °C ≤ Ta ≤ +50 °C
Certification
Ex II 3 (2)G Ex ec [ib IIC or IIB Gb] IIC T4 Gc
Ex II (2)D [Ex ib IIIC]
Ex ec [ib IIC or IIB Gb] IIC T4 Gc
Ex tc [ib IIC or IIB Gb] IIIC T120°C Dc
(-13 °F ≤ Ta ≤ +122 °F )
USB Barrier Exi for connecting intrinsically safe input devices of the POLARIS and POLARIS II series to a standard PC.
The USB Barrier Exi is installed in the safe area or may also be installed as associated equipment in Zone 2.
Technical Data
| Structure | 2-fold USB hub |
|---|---|
| Dimensions (without cable glands) |
190x75x50mm |
| Housing material | Polyester housing |
| Ambient temperature | From -25°C to +50°C |
| Supply voltage | USB PC (500mA) |
| Supply voltage (optional) |
USB Y cable, for separate input (USB: 5 V ) |
| Maximum power consumption |
Pmax < 2,5 W |
| Relative humidity | From 5 to 95 % non-condensing |
| Input | USB 2.0 |
| Output | 2 x USB Exi |
Manuals/Operating Instructions/Guides
- DE
- EN
Data Sheets