Marking
Ex protection control unit and power unit:
ATEX:
Ex II 2 G Ex db eb mb IIC T4 Gb
IECEx:
Ex db eb mb IIC T4 Gb
Ambient Temperature
Certification
-
ATEX
- EN
-
IECEx
- EN
-
EAC
- RU
The EXguard® system is a further development of our TN2000-5 System, which is designed for use on refineries and onshore plants. The EXguard® system is especially designed for use during hot work operation for onshore and offshore installations for detection, alarm and shutdown in case explosive gases are present. The EXguard® system is especially designed for use in ATEX and IECEx zone 1 and 2 during hot work operation as well as inside habitats. Upon detection of explosive gas, connected electrical equipment and pneumatic tools are automatically shut down, and audible and visual alarm will be given.
| Structure | Lifting lugs: 2 each unit Mobility: Wheeled, lifted PLC: OMRON Detector cable: Radox Tenuis-TW/S EMC Sensor: Simrad Optronics GD10P, other sensors upon request |
|---|---|
| Dimensions | Dimension Control Unit (incl. equipment): H x W x D = 680 x 1275 x 625 mm Dimensions Power Unit (incl. equipment): H x W x D = 820 x 1290 x 625 mm |
| Material | Material gas sensor and cable drum: Stainless steel 316L/CF3M Material trolley and electrical enclosures: Stainless steel 316L/CF3M |
| Weight | Total weight (control unit): 105 kg Total weight (power unit): 85 kg |
| Voltage | Rated voltage Control Unit: 220 – 240 VAC 50/60 Hz (standard) Rated voltage Power Unit: 380 – 690 VAC 50/60 Hz (must be specified) |
| Current | Max. current in/out Control Unit: 16A Max. current in/out Power Unit: 63A |
Accessories/System Overview
- EN
Data Sheets