Marking
Ex protection type Ex i = Version 0:
Ex II 2(1)G Ex db e [ia Ga] IIC Gb
Ex I M2 Ex db e [ia Ma] I Mb
Ex db e [ia Ga] IIC Gb
Ex db e [ia Ma] I Mb
Class I, Zone 1, IIC
A/Ex d e [ia] IIC Gb
Ex protection type Ex e = Version 1:
Ex II 2G Ex db e IIC Gb
Ex I M2 Ex db e I Mb
Ex db e IIC Gb
Ex db e I Mb
Class I, Zone 1, IIC
A/Ex d e IIC Gb
Ambient Temperature
-25 °C to +60 °C at T4
Certification
-
ATEX
- DE
- DE
- EN
- EN
-
IECEX
- EN
- EN
-
CSA
- EN
-
INMETRO
- PT
- PT
In the Ex i or Ex e version, the MODEX 8 x 4 to 20 mA module can control various actuators depending on the model using 8 analogue short-circuit proof outputs. The controlled actuators can be switched off by an emergency stop via a second power supply connection on the module on terminals U- and U+. The module is connected to the process control system via the PROFIBUS-DP. Coding rotary switches are available for addressing the module. Diagnostics data indicating the status of the outputs with respect to a disconnection or short-circuit can also be transmitted in addition to the user data. This is also displayed on the module itself using LEDs.
Technical Data:
| Protection class | Module: IP 66 EN/IEC 60529 Terminals: IP 20 EN/IEC 60529 Terminals with cover: IP 30 EN/IEC 60529 |
|---|---|
| Structure | Flameproof, clip-on enclosure for TH 35 rail |
| Dimensions | see data sheet |
| Material | High-quality thermoplastic |
| Storage temperature | -40 °C to +60 °C |
| Weight | 2.1 kg |
| Display | LEDs on front panel Status: ON, BF, SF, UB2 Outputs: 8 x double LED LED yellow, output ok; LED red, short circuit |
| Voltage | Supply voltage (L+, L-): DC 24 V (20 to 30 V) |
| Output power | 1.8 W 5.7 W (Output) |
| Power dissipation | 7.5 W (Module) |
Other:
- GSD
Manuals/Operating Instructions/Guides:
- DE
- EN
- FR
Declarations:
- DE
- EN
- FR
Data Sheets:
Brochures:
-
MODEX Flyer
- DE
- EN
-
MODEX system description
- EN
- DE
Documents:
-
MODEX Flyer
- ES
- FR
- IT
- PT
- RU
- TR
-
MODEX_07-7331-_170x102x96_mm.stp
- STP